Mandatory Technical Directive, MTD-05-2024Â has been issued today to introduce mandatory checks on the clearance between the distributor cap and rotor arm in Jabiru 2200 engines where the cap or rotor have recently been changed (or following subsequent changes). This follows an in-service finding where differences in distributor cap design were found which lead to extreme wear in the components causing the engine to stop.
The MTD must be carried out before further running of the engine on or after 10th July 2024 on Jabiru 2200 engines where the distributor cap and/or rotor arm has been changed in the last 20 engine hours, or are subsequently changed. The checks are also recommended on all other Jabiru 2200 engines.